Call 07942536137 85% Response Rate

Send Enquiry

our range

Protection Relays

Pioneers in the industry, we offer current protection relay - digital din rail mount, overload relay 3phase-ct built-in, water level controller, digital temperature indicator, earth fault relay - din rail mount and multispan power factor correction 16 stage from India.

Current Protection Relay - Digital Din Rail Mount

  • Current Protection Relay - Digital Din Rail Mount
  • Current Protection Relay - Digital Din Rail Mount
  • Current Protection Relay - Digital Din Rail Mount
Current Protection Relay - Digital Din Rail Mount
Get Best Quote
Price on Request
Current Rating5A
Voltage TypeAC
Country of OriginMade in India
Primary CT value5 to 999 Selectable
Resolution0.01A, 0.1A, 1A
Supply voltage100 to 250V AC, 50-60Hz

Product: CPR-35

 

  • Programmable Over & Under Current
  • 1-Relay, 1-C/O
  • Fail Safe & Non Fail Safe Mode
  • Available in 1Ø and 3Ø
  • Size: (H)90mm X (W)35mm X (D)61.5mm
  • Supply Voltage: 100-270V AC
INPUT SPECIFICATION
Primary CT value 5 to 999 Selectable
Secondary current AC 0.05 to 5 Amp AC
Resolution 0.01A, 0.1A, 1A
DISPLAY AND KEY:
Display UPPER : 3-Digit, 7-Seg 0.4”
LOWER : 3-Digit, 7-Seg 0.28”
Keys SET, INC, DEC/ RST
OUTPUT SPECIFICATION:
Relay 1 nos.
Relay Type 1 C/O (NO-C-NC)
Rating 5A, 250V AC/30 V DC
ACCURACY Class 1.0 (Standard)
GENERAL SPECIFICATION:
Dimension (mm) 90 (H) x 35 (W) x 61.5 (D) 
Trip Setting Under current: 0.00 to 100% of primary C.T value
Over current: 0.00 - 120% of primary C.T value
Time parameter Trip delay time : 0 to 999 sec 
Power on time : 0 to 99 sec 
Initial time delay : 0 to 99 sec 
Recovery time : 0 to 99 sec
AUXILIARY SUPPLY:
Supply voltage 100 to 250V AC, 50-60Hz
Power consumption (VA RATING) 3 VA @ 230V AC MAX
ENVIRONMENT CONDITION:
Operating Temp. 0°C to 55°C
Relative Humidity Upto 95% RH
(non-condensing)
 Application
  • DG Set Panels
  • Motor Control Center Panels
  • Control Panels
  • Distribution Panels
  • Process Control

View Complete details

Yes! I am Interested Request a call back

Overload Relay 3Phase-CT Built-in

  • Overload Relay 3Phase-CT Built-in
  • Overload Relay 3Phase-CT Built-in
  • Overload Relay 3Phase-CT Built-in
Overload Relay 3Phase-CT Built-in
Get Best Quote
Price on Request
Usagefor Transformers
Current Rating50 to 100A AC
Mounting TypeDIN Rail
PhaseThree phase
Tripping ParametersOver Current, SPP

Product: Multispan OLR-50100

 

  • Range 50-100A AC
  • Trip and Power On Delay 0-9 Sec
  • 1 Relay 1C/O, 5A,230V AC
  • Front Test and Rest Key
  • Size: 70 X 70.5 X 91 (H X W X D) mm
  • Supply Voltage : 230V AC
ParameterSpecification
Power Supply 230V AC, 50Hz
Input Current 50 to 100A AC
Output 1 Relay NO/C/NC, 5A 230V AC, 30V DC Resistive load
Tripping Parameters Over Current, SPP
Delay Time Power ON Delay: 0 To 9 Sec Settable
Initial Time Delay: 5 Sec
Reset Mode: Manually
Trip Time Trip Time Delay: 0 To 9 Sec Settable
Keys Test, Reset

View Complete details

Yes! I am Interested Request a call back

Water Level Controller

  • Water Level Controller
  • Water Level Controller
  • Water Level Controller
Water Level Controller
Get Best Quote
Price on Request
PhaseThree Phase
Voltage230V AC
Input6 Probes
Output Rating5Amp, 230V AC (Resistive)
Sensitivity1K to 1M ohms
Trip Delay0 to 10 sec (Selectable)
MountingDin Rail Mounting

Product: MULTISPAN WLC-35

 

  • Input: 6 Probes
  • Sensitivity Adjustable: 1K Ohm to 1M Ohm
  • Delay Time (0-10) Sec.
  • High & Low-Level Indication LED for Lower & Upper Tank
  • Pump protection from Dry run & Overflow condition
  • Size: (H)90mm x (W)35mm x (D)62.5mm
  • Supply Voltage: 100-270V AC, 50/60Hz
Model WLC 35
Mounting Din Rail Mounting
Input Sensor 6 nos. prods
  S1: Common     S1: Common (Upper)
S2: Low             S2: Low (Upper)
S3: High            S3: High (Upper)
Indications LED 1: Relay
LED 2: High Level (Lower)
LED 3: Low Level (Lower)
LED 4: Mains
LED 5: High Level (Upper)
LED 6: Low Level (Upper)
Power Supply 100 270V AC, 50/60 Hz, 3VA
Output Rating 5Amp, 230V AC (Resistive)
Dimension 90 x 35 x 62.5 mm
Output 1 Relay, 1 C/O (NO-C-NC)
Sensitivity 1K to 1M ohms
Reset Auto
Trip Delay 0 to 10 sec (Selectable)

View Complete details

Yes! I am Interested Request a call back

Digital Temperature Indicator

  • Digital Temperature Indicator
  • Digital Temperature Indicator
Digital Temperature Indicator
Get Best Quote
Price on Request

Product Brochure

Display TypeLCD
Model Name/NumberTI-11-A2=02
ColorBLACK
Country of OriginMade in India
RANGEJ-600
SENSORJ TYPE
AUX VOLTAGE100 TO 270V AC
TRANSWORLD AUTOMATION(LUDHIANA)           MODEL-TI-11-A2-02                                           USAGE/APPLICATION-FOR INDUSTRIAL            WE SELL BEST PRODUCTS DIFFERENT MODELS DIFFERENT MAKE ON BEST PRICES.

View Complete details

Yes! I am Interested Request a call back

Earth Fault Relay - Din Rail Mount

  • Earth Fault Relay - Din Rail Mount
  • Earth Fault Relay - Din Rail Mount
  • Earth Fault Relay - Din Rail Mount
  • Earth Fault Relay - Din Rail Mount
  • Earth Fault Relay - Din Rail Mount
  • Earth Fault Relay - Din Rail Mount
Earth Fault Relay - Din Rail Mount
Get Best Quote
Price on Request

Product Brochure

Current Rating5A
Voltage100 To 270 V AC
Country of OriginMade in India
Input Current5 Amp. AC From CBCT OR CT
Range10% to 100%

Product: EFR-63

 

  • Input thru External CBCT
  • Front and Terminal Test and Reset Function
  • Programmable trip Delay
  • 1 Relay 1 C/O,5A,230V AC
  • Size: 76 X 28 X 85 (H X W X D) mm
  • Supply Voltage : 100-270V AC
INPUT SPECIFICATION :
Input Current 5 Amp. AC From CBCT OR CT
Range 10% to 100%
Resolution 1%
DISPLAY & KEYS :
Display 3 Digit, 7 Seg., 0.36”, Red.
Keys SET, INC, DEC.
OUTPUT SPECIFICATION :
Relay 1 Nos.
Relay Type NO - C
Rating 5A,230V AC Resistive Load
AUXILIARY SUPPLY :
Supply Voltage 100 To 270 V AC
Power Consumption (VA Rating) 3VA @ 230 VAC MAX
ENVIRONMENT CONDITION:
Operating Temp. 0 - 55°C
Relative Humidity 95% RH

View Complete details

Yes! I am Interested Request a call back

Multispan Power Factor Correction 16 Stage

  • Multispan Power Factor Correction 16 Stage
  • Multispan Power Factor Correction 16 Stage
  • Multispan Power Factor Correction 16 Stage
Multispan Power Factor Correction 16 Stage
Get Best Quote
Price on Request

Product Brochure

PhaseThree Phase
Rated CurrentAbove 6300 Amps
Automation GradeAutomatic
Power300V to 520V AC , 50Hz
BrandMultispan
Input Current Range10mA to 5Amp AC (Without CT) (CT Ratio Selectable 5/5A AC to 9999/5A) for Main CT & Capacitor CT
Input Voltage Range300 to 520 V AC
DisplayUpper: 4 Digit,7 seg,0.60"White Lower: 7 Digit,7 seg,0.38"Green
Memory Retention10 Years
AccuracyClass 0.5 ( Standard )
Relay16 Relay with 1 NO-C for capacitor bank

Product: APFC-116

Features:

  • Single CT,  Capacitor CT,2Ø Voltage Input
  • 8,12,14,16 stage available
  • Auto/Manual/Rotation Mode
  • With Alarm Output 
   Application
  • PF Management using Single CT Method
  • For 3Ø Balanced Industrial Loads
  • Energy Monitoring System
  • DG Set Panels
  • Process Control
  • Power Factor Correction Panels
  • Commercial Buildings

View Complete details

Yes! I am Interested Request a call back

Current Protection Relay - Din Rail Mount

  • Current Protection Relay - Din Rail Mount
  • Current Protection Relay - Din Rail Mount
  • Current Protection Relay - Din Rail Mount
Current Protection Relay - Din Rail Mount
Get Best Quote
Price on Request
BrandMultispan
Voltage100-270V AC
Current200mA to 5Amp AC
Relay TypeVoltage Relay
Model Name/NumberCR-3K
Usage/ApplicationDG Set Panels Motor Control Center Panels Control Panels Distribution Panels Process Control
Country of OriginMade in India

Product: CR-3K

 

  • Programmable Over & Under Current
  • 1-Relay, 1-C/O,5A,230V AC
  •  Digital Display 3+3 Digit in Din Rail Mount
  • Size: (H)90mm X (W)35mm X (D)62.5mm
  • Supply Voltage: 100-270V AC

Parameter

Specification

Power Supply 100-270V AC
Input Current 200mA to 5Amp AC
Rated Current 5A
Output 1-Relay, 1-C/O, 5A, 230V AC Resistive load
Tripping Parameters - Under Current
- Over Current
- SPP (Single Phase Perversion)
RESET MODE ZVR (Zero Value Reset)

View Complete details

Yes! I am Interested Request a call back

Analog Voltage Protection Relay - Din Rail Mount

  • Analog Voltage Protection Relay - Din Rail Mount
  • Analog Voltage Protection Relay - Din Rail Mount
  • Analog Voltage Protection Relay - Din Rail Mount
Analog Voltage Protection Relay - Din Rail Mount
Get Best Quote
Price on Request
Voltage280 to 520V AC
Country of OriginMade in India
Rated Voltage415V AC (L-L)
Output1-Relay, 1-C/O, 5A 230V AC Resistive Load
Reset ModeAuto
Product: VR-3K

  • Selection of Under- Over Voltage and Trip Delay by Knob
  • 1-Relay, 2-C/O, 5A,230V AC
  • Size: (H)90mm X (W)35mm X (D)62.5mm
  • Self-Powered
ParameterSpecification
Power Supply Self Power
Input Voltage 280 to 520V AC (L-L) 3Ø -3W
Rated Voltage 415V AC (L-L)
Output 1-Relay, 1-C/O, 5A 230V AC Resistive Load
Tripping Parameters Under Voltage
Over Voltage
Phase Asymmetry
Phase Sequence
Phase Loss
Reset Mode Auto

View Complete details

Yes! I am Interested Request a call back

Voltage Protection Relay- Digital Din Rail Mount

  • Voltage Protection Relay- Digital Din Rail Mount
  • Voltage Protection Relay- Digital Din Rail Mount
  • Voltage Protection Relay- Digital Din Rail Mount
Voltage Protection Relay- Digital Din Rail Mount
Get Best Quote
Price on Request
BrandMultispan
Voltage160 to 300V AC (L - N) 3-4W, 280 to 520V AC (L - L) 3-3W
Relay TypeVoltage Relay
Model Name/NumberVPR-33
Usage/ApplicationDG Set Panels Motor Control Center Panels Control Panels Distribution Panels
Frequency45.0 Hz to 65.0 Hz
Country of OriginMade in India

Product: Multispan VPR-33

 

  • 3 + 3 Digit , 7-Segment Red + Green or Red + White LED for Bright Visibility
  • 2-Relay Option Available
  • Programmable Tripping Parameter On
  • Over & Under Voltage, Phase Asymmetry, Phase Loss, Phase Sequence, Neutral Loss 
  • Individual Enable /Disable Tripping Parameter
  • More Accurate and Immediate Tripping
  • Fail Safe and Non Fail Safe Mode
  • Size: (H)90mm X (W)35mm X (D)61.5mm

 

INPUT SPECIFICATION
Direct Voltage AC 160 to 300V AC (L - N) 3Ø-4W
280 to 520V AC (L - L) 3Ø-3W
Frequency 45.0 Hz to 65.0 Hz
Resolution 1 Volt
Accuracy Class 1.0
DISPLAY AND KEY :
Display UPPER: 3-Digit, 7-Seg, 0.4"
LOWER: 3-Digit, 7-Seg, 0.28"
Keys SET, INC, DEC/RST
GENERAL SPECIFICATION :
Dimension (mm) 90 (H) x 35 (W) x 61.5 (D) 
Trip Setting Under Voltage: 260-520V AC 3Ø-3W 160-300V AC 3Ø-4W
Over Voltage: 260-520V AC 3Ø-3W 160-300V AC 3Ø4W
Under Frequency: 45.0 Hz To 65.0 Hz 
Over Frequency: 45.0 Hz To 65.0 Hz 
Phase Asymmetry: (10-100V) 
Hysteresis: (0-99V)
Time Parameter Power ON Delay Time : 0.0 To 99.9 Sec.
Trip Delay Time : 0.0 To 999 Sec. 
Recovery Time : 0.0 To 99.9 Sec.
Accuracy Class 1.0 (Standard)
OUTPUT SPECIFICATION
Relay 2 nos.
Relay Type 1-C/O (NO-C-NC)
Rating 5A, 230V AC Resistive Load
24V DC
ENVIRONMENT CONDITION
Operating Temp. 0°C to 55°C
Relative Humidity Upto 95% RH
(non-condensing)
Protection Level (As per request) IP-65 (Front side) As per IS/IEC 60529 : 2001
NETWORK CONNECTION
3Ø-3W/3Ø-4W

View Complete details

Yes! I am Interested Request a call back

Multifunction Protection Relay 3 Phase ( Din Rail Mount )

  • Multifunction Protection Relay 3 Phase ( Din Rail Mount )
  • Multifunction Protection Relay 3 Phase ( Din Rail Mount )
  • Multifunction Protection Relay 3 Phase ( Din Rail Mount )
Multifunction Protection Relay 3 Phase ( Din Rail Mount )
Get Best Quote
Price on Request
BrandMultispan
Voltage100 to 270V AC
Current5 to 6000 Amp selectable
Relay TypeVoltage Relay
Model Name/NumberMPD-152
Usage/ApplicationElectrical Control Panel Submersible Pump Road Construction Panel
Frequency45.0 to 65.0 Hz
Country of OriginMade in India

Product: MPD-152

 

  • 3 Line – 3 Digit Display for Easy to Use and Understand 3 Phase Value
  • 3 Phase 3 Wire / 4 Wire Selectable
  • Display 3 Phase Voltage (Ph-Ph, Ph-N), 3 Phase Ampere & Frequency
  • Programmable Tripping Parameter
  • Single Instrument works for Both VAF Monitoring and Protection Relay
  • Programmable Relay 1 Relay 2 C/O
  • Fail Safe and Non Fail Safe Mode
  • Size: 75 X 55 X 110 (H XW X D) mm
  • Supply Voltage : 100-270V AC
INPUT:
Voltage AC
Direct Voltage AC 30 to 300V(L - N)
50 to 520V(L - L)
Burden < 0.2VA
Current AC
Primary CT Ratio 5 to 6000 Amp selectable
Secondary Current AC 0.5 to 5 Amp
Burden < 0.2VA
Overload Up to 6A continuous
Frequency 45.0 to 65.0 Hz
DISPLAY AND KEYS :
Display 3 Digit, 3 Line 7 Seg 0.28”,
RED LED
Keys SET, INC, DEC, RST
DIMENSION :
Size (mm) 75(H)X 55(W)X110(D)
NETWORK SELECTION : 3 Phase - 4 Wire,3 Phase - 3 Wire,
ACCURACY: Class 1.0 (Standard)
TRIP SETTING:
Under Current 0.00 to CTR
Over Current 0.00 to CTR
Under Voltage 50 to 520V For 3Ø - 3W
30 to 300V For 3Ø - 4W
Over Voltage 50 to 550V For 3Ø - 3W
30 to 330V For 3Ø - 4W
Over / Under Frequency 45.0 to 65.0 Hz
Short Circut 1 - 9 Scale
Lock Rotor Point 0.5 to 9.0 Scale
Unbalance 5 - 60%
TIME PARAMETER:
Power On Delay 0 to 99 Sec
Initial Time Delay 0 to 99 Sec
Trip Delay Time(Voltage, Current, Frequency, SSP, Unbalance) 0 to 999 Sec
Scrolling Time 1 to 99 Sec
Reset Time 0 to 99 Sec
OUTPUT SPECIFICATION :
Relay 1 Nos
Relay Type 1 C/O (NO-C-NC)
Rating 10Amp, 250V AC
AUXILIARY SUPPLY :
Supply Voltage 100 to 270V AC, 50Hz
Power Consuption 3VA @ 230 AC MAX
ENVIRONMENTAL CONDITION:
Working Temperature 0 to 55°C
Storage Temperature 0 to 55°C
Relative Humidity 95 % RH Non-Condensing
  Application
  • Electrical Control Panel
  • Submersible Pump
  • Road Construction Panel
  • MCC Panel
  • Industrial Chiller And HV AC System
  • D.G. Set

View Complete details

Yes! I am Interested Request a call back

10A Earth Leakage Relay Panel Mount

  • 10A Earth Leakage Relay Panel Mount
  • 10A Earth Leakage Relay Panel Mount
  • 10A Earth Leakage Relay Panel Mount
10A Earth Leakage Relay Panel Mount
Get Best Quote
Price on Request
Current Rating10A
Voltage TypeAC
Country of OriginMade in India
Input Current30 mA To 3.00 Amp AC
Display Currant Range0.030 To 3.000 Amp AC
ResolutionIf Current in mA = 1 mA If Current in Amp = 0.001A

Product: Multispan ELR-19N

 

  • 4+4 Digital Display for Indication of Leakage and Set Current
  • 1-Relay, 1-C/O,5A,230V AC
  • Fail Safe and Non Fail Safe Mode
  • RS-485 Modbus Available
  • Size: (H)96mm X (W)96mm X (D)54mm
  • Supply Voltage: 100-270V AC/DC
INPUT SPECIFICATION
Input Current 30 mA To 3.00 Amp AC
Display Currant Range 0.030 To 3.000 Amp AC
Resolution If Current in mA = 1 mA If Current in Amp = 0.001A
DISPLAY & KEYS :
Display Upper: 4-Digit ,7-Seg, 0.56”, Red
Lower: 4-Digit ,7-Seg, 0.56”,White
Keys SET, INC, DEC, ENT/RST
DIMENSION : 
Size (mm) 96 (H) X 96 (W) X 54 (D)
Panel Cutout (mm) 92 (H) X 92 (W)
OUTPUT SPECIFICATION :
Relay 1 Nos.
Relay Type 1-C/O (NO-C-NC)
Rating 10A,230V AC Resistive Load
AUXILIARY SUPPLY :
Supply Voltage 100 To 250 V AC,50/60Hz
Power Consumption (VA Rating) 4VA @ 230 VAC MAX
ENVIRONMENT CONDITION:
Operating Temp. 0°C to 55°C
Relative Humidity Upto 95% RH
(non-condensing)
Protection Level
(As per request)
IP-65 (Front side) As per IS/IEC 60529 : 2001
   Application
  • Control & Relay Panel
  • Energy Management System
  • DG Set Panels
  • LT / HT Panel
  • Power Control Center Panels
  • Motor Control Center Panels

View Complete details

Yes! I am Interested Request a call back

Earth Leakage Relay- BUILT IN CBCT ID 35 mm

  • Earth Leakage Relay- BUILT IN CBCT ID 35 mm
  • Earth Leakage Relay- BUILT IN CBCT ID 35 mm
  • Earth Leakage Relay- BUILT IN CBCT ID 35 mm
Earth Leakage Relay- BUILT IN CBCT ID 35 mm
Get Best Quote
Price on Request
Current Rating5A
Voltage TypeAC
Country of OriginMade in India
Input Current0.00 To 3.00 A AC in CBCT
Display Currant Range30mA To 3.00 Amp
ResolutionIf Current in mA = 1 mA If Current is Amp Above = 0.01A

Product: Multispan ECT-35D

  • Range 30mA to 3A AC
  • No Need of Separate CBCT as Built in CBCT (ID 35mm)
  • Digital Display for Programming Leakage Setting and Trip Delay
  • 1-Relay, 1-C/O, 5A, 230V AC
  • With Front Key and Terminal Reset and Test Function
  • Size: (H)76mm X (W)40mm X (D)103mm
  • Supply Voltage: 100-270V AC/DC
INPUT SPECIFICATION :
Input Current 0.00 To 3.00 A AC in CBCT
Display Currant Range 30mA To 3.00 Amp
Resolution If Current in mA = 1 mA
If Current is Amp Above = 0.01A
DISPLAY & KEYS :
Display 3-Digit, 7-Seg., 0.28”, Red.
Keys Test, Rst
OUTPUT SPECIFICATION :
Relay 1 Nos.
Relay Type NO - C- NC
Rating 5A,230V AC Resistive Load
AUXILIARY SUPPLY :
Supply Voltage 100 To 270 V AC/DC
Power Consumption (VA Rating) 3VA @ 250 VAC MAX
ENVIRONMENT CONDITION
Operating Temp. 0 - 55°C
Relative Humidity 95% RH
  Application
  • Control & Relay Panel
  • Energy Management System
  • DG Set Panels
  • LT / HT Panel
  • Power Control Center Panels
  • Motor Control Center Panels

 

View Complete details

Yes! I am Interested Request a call back

Multispan Earth Leakage Relay Analog Din Rail

  • Multispan Earth Leakage Relay Analog Din Rail
  • Multispan Earth Leakage Relay Analog Din Rail
  • Multispan Earth Leakage Relay Analog Din Rail
Multispan Earth Leakage Relay Analog Din Rail
Get Best Quote
Price on Request
Current Rating5A
Voltage TypeAC
Country of OriginMade in India
Input Current30mA To 30A AC From CBCT
Set Currant Range0.03A To 30Amp
Trip Delay Time0 to 10 Second

Product: Multispan ER-2K

 

  • Range: 30mA to 30A AC
  • Programmable Set and Trip Delay by Knob
  • 1-Relay 1-C/O,5A,230V AC
  • With Front Key and Terminal Reset and Test Function
  • Size: (H)90mm X (W)35mm X (D)62.5mm
  • Supply Voltage: 100-270V AC
INPUT SPECIFICATION :
Input Current 30mA To 30A AC From CBCT
Set Currant Range 0.03A To 30Amp
Trip Delay Time 0 to 10 Second
KEYS :
Keys Test, Rst
OUTPUT SPECIFICATION
Relay 1 Nos.
Relay Type NO - C - NC
Rating 5A,230V AC Resistive Load
AUXILIARY SUPPLY :
Supply Voltage 100 To 270 V AC
Power Consumption (VA Rating) 2VA @ 230 VAC MAX
ENVIRONMENT CONDITION
Operating Temp. 0 - 55°C
Relative Humidity 95% RH

View Complete details

Yes! I am Interested Request a call back

Phase Sequence Relay Din Rail

  • Phase Sequence Relay Din Rail
  • Phase Sequence Relay Din Rail
Phase Sequence Relay Din Rail
Get Best Quote
Price on Request
Current Rating5A
Voltage TypeAC
Country of OriginMade in India
System3 Phase 3 Wire Input
Supply Voltage280 to 520V AC (L-L)
Phase Loss< 280V AC (L-L)
Phase Asymmetry>40V AC (L-L)
Product: Multispan V22-RYB

  • 3 Phase 3 Wire Input
  • Separate Aux supply not needed as it is self-powered
  • Tripping parameter : Phase Sequence, Phase Loss & Phase Asymmetry 
  • 1 Relay 1 C/O
  • Unique features for Tripping Fault Identifications : Front R-Y-B LED Indication
  • Size: 90 X 22.5 X 72 (H XW X D) mm
System 3Ø - 3W
Supply Voltage 280 to 520V AC (L-L)
Phase Loss < 280V AC (L-L)
Phase Asymmetry >40V AC (L-L)
Hysteresis 6 V Fix (For Auto Reset)
Reset Auto Reset on Healthy Condition
Output

1 C/O,
5 A 230V AC
5A, 28V DC
(Resistive Load)

Power ON Delay 5 Second
Trip Delay PS & PL < 200ms Asy : 5 Sec.

View Complete details

Yes! I am Interested Request a call back

Current Protection Relay - Digital Panel Mount

  • Current Protection Relay - Digital Panel Mount
  • Current Protection Relay - Digital Panel Mount
  • Current Protection Relay - Digital Panel Mount
Current Protection Relay - Digital Panel Mount
Get Best Quote
Price on Request
CT Setting5 to 4000 Selectable
Input Rating0.5 to 5 Amp AC
Output Rating10A, 230V AC / 28V DC
Voltage TypeAC
Country of OriginMade in India

Product: Multispan CC-12

 

  • 4+4 Digit
  • Programmable Over and Under Current
  • 1-Relay, 5A, 230V AC
  • Size: (H)96mm X (W)96mm X (D)43mm
  • Supply Voltage: 100-270V AC

View Complete details

Yes! I am Interested Request a call back